| 04:06 02/16/2009
|
| NON FERROUS-NON SHRINKAGE GROUT |
 |
|
|
Composition Special Portland cement with time-released expansive agent and carefully graded silica aggregate. Benefits Just add water to use. Will harden free of settlement or dry shrinkage with a unique controlled expansion. Can be used at any consistency from fluid to plastic. Can be pumped into inaccessible areas. Appearance is very similar to natural concrete or mortar. Will not rust or stain. Low water/cement ratio results in early strength with exceptional bearing contact. For large pours, increase yield with addition of up to 25% by weight of clean, well graded aggregate. Packaging 50 lb. (22.5kg), or 100 lb. (45kg) multi-wall bag with moisture resistant liner. Freight Class: NMFC Item No. 42140 Class 55 TECHNICAL DATA - LABORATORY TEST RESULTS Data derived from laboratory tests. Actual results will vary with field conditions.
Mix Consistency
| Minimum Flow (Plastic)
| Moderate Flow (Pourable)
| High Fluidity (Pumpable)
| Flow Test
| CRD-C226 at 5 drops 100 flow index
| CRD-C2226 at 5 drops 124 flow index
| CRD-C611 26 second flow cone
| Expansion 3 days 14 days 28 days
| +0.08% +0.08% +0.08%
| +0.04% +0.04% +0.08%
| 0.00% +0.02% +0.04%
| Mix Consistency
| Minimum Flow (Plastic)
| Moderate Flow (Pourable)
| High Fluidity (Pumpable)
| Compressive 1 day Strength 3 days 7 days 28 days
| 5,400 psi 8,120 psi 9,330 psi 12,340 psi
| 4,410 psi 7,570 psi 8,490 psi 11,270 psi
| 2,870 psi 6,420 psi 8,340 psi 9,760 psi
|
SPECIFICATIONS Complies with Corps of Engineers specification CRD-C621-83 (formerly CRD-C 588-78) and ASTM C-827-78. APPLICATION INSTRUCTIONS Surface Preparation Clean all surfaces of grease, oil, dirt and loose material, down to sound concrete. Roughen adjacent concrete surfaces where possible. Wet area thoroughly at least 4 hours prior to grouting. Remove excess water before placement. Forms must be strong, securely anchored, shored and sealed to prevent grout leakage.
Mix Consistency
50 lbs.(22.5kg) grout
| Minimum Flow (Plastic)
| Moderate Flow (Pourable)
| High Fluidity (Pumpable)
| Clean Water
| 2 3/4 qts.
| 3 1/8 qts.
| 4 qts.
| Yield
| .39 cu. ft.
| .405 cu. ft.
| 415 cu. ft.
| DO NOT DRY OR DAMP PACK. USE DAMP PACK GROUT. WATER QUANTITIES ARE ONLY A GUIDE. For best results add dry grout to water; not water to dry grout. Temperature, mixing method, and batch size will determine the actual amount of water required to place grout correctly.; Use the minimum amount of water needed for placement. Use a mechanical mixer for approximately 5 minutes to ensure a uniform mixture, and place. Mix as close to the grouting area as possible. Mix only enough grout that can be placed in 15 minutes. Working time is approximately 30 minutes at 21oC (70oF). Placement Grout must be placed continuously and from one side avoiding the entrapment of air pockets. Sufficient vent holes should be provided. Remove voids through rodding and vibrating. When grouting areas of more than 3" in depth, add up to 25% by weight washed pea gravel that is 3/8" or less in size. Then mix and place as outlined. Should pea gravel not be available, any placement above 3" should be done in pours 24 hours apart. After placement, keep exposed surfaces damp. Protect from excessive heat and cold. Keep from drying out for up to 3 days, or apply a curing compound, such as Penetron Cure. NON FERROUS NON SHRINK GROUT is a cementitious product. Follow ACI recommendations for forming and placement. After initial mixing, do not retemper. Caution! Skin may be sensitive to cement. Wearing rubber gloves is recommended. Avoid contact with eyes or prolonged contact with skin. If eye contact occurs, flush immediately with water. KEEP OUT OF THE REACH OF CHILDREN. SUGGESTED0 SHORT FORM ARCHITECTURAL SPECIFICATION Non-Shrink Grout shall be Penetron NON FERROUS NON SHRINK GROUT as manufactured by ICS/Penetron International, Ltd., East Setauket, New York. NON FERROUS NON SHRINK GROUT shall comply with U.S. Corps of Engineers CRD-C 621-82B "Specification for Non-Shrink Grout." WARRANTY ICS/Penetron International, Ltd. products will perform according to specifications only if directions are followed. Penetron is not responsible for improper use, application, or storage of its products or for use of its products in unsafe weather or with unsafe engineering or working conditions. Penetron products are supplied subject to Penetron's standard terms and conditions of sale or rental, which limit Penetron responsibility for the product. Any warranty of the product is limited to Penetron's or the manufacturer's standard warranty unless otherwise specifically provided by Penetron in writing.
|
|
 |
|
|